{"product_id":"allcare-digital-tens-unit-1unit","title":"AllCare Digital TENS Unit","description":"\u003ch2\u003e\u003cspan\u003eGeneral Information\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eA dual channel digital TENS with memory function that can store the treatment time used by the patients. The Physical Therapist can then check the units to make sure the unit is used as suggested. This device has a large liquid crystal display and press buttons, which is a great design for people who have difficulty reading the small inscription on the panel or turning the small dials.\n\nFeatures:\n12 Preset Programs\nChannel: Dual, isolated between channels\nPulse Amplitude: 0-80mA peak to peak into 500 ohm load\nPulse Rate: Adjustable, from 1Hz ~ 150 Hz, 1 Hz\/step\nPulse Width: Adjustable, from 50 uS ~ 300 uS, 10 uS\/step\nMode: B, N, M, S1, S2\nTIMER: Selectable, 15, 30, 60 Minutes\nWave Form: Asymmetrical Bi-Phasic Square Pulse\nVoltage: 0-40 V peak into 500 ohm load\nSupplied with the following accessories:\n1 x Carry Case\n2 x TENS Leads\n1 x Operating Manual\n1 x 9V Battery\n1 x Pack of AllCare Self-Adhesive Electrodes (4 Electrodes per pack)\n\nARTG No: 220257\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCommon Uses\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eTranscutaneous Electrical Nerve Stimulation (TENS) is used to treat a variety of pain conditions. TENS units are small, battery-powered devices that use low-voltage electrical currents to stimulate nerve cells and increase endorphins\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eDirections\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eStep 1: Attach the pads: Place the pads on or around the painful area. You can try placing one pad on the painful area and the other a few centimeters away. \n\nStep 2: Turn on the machine: With the pads attached, turn on the machine.\n \nStep 3: Adjust the intensity: Start on a low setting and gradually increase the intensity until you feel a slight tingling sensation. The sensation should feel comfortable, not painful. \n\nStep 4: Use the machine: You can use the machine for a specific area or for a larger area. For larger areas, you can use more electrodes. \n\nStep 5: Turn off the machine: When you're finished, turn off the machine and remove the pad.\u003c\/p\u003e\u003cp\u003eStep 1: Clean the unit\nTurn off the unit and use a soft, slightly damp cloth to gently wipe it down. Avoid using chemical cleaners or rubbing alcohol. \n\nStep 2: Remove the lead wires\nCarefully take the lead wires out of the patches. Pulling on the wires can damage the electrodes. \n\nStep 3: Store the patches\nIf you're taking off the patches, gently peel them off your skin and place them back onto the plastic liner. Put the liner and patches in a plastic storage bag. \n\nStep 4: Store in a cool, dry place\nKeep the bag in a cool, dry place until you're ready to use the unit again. \n\nStep 5: Charge rechargeable batteries\nIf the unit has rechargeable batteries, charge them according to the manufacturer's instructions. Batteries may lose their charge after being stored for 60 days or more. \n\nStep 6: Keep the plastic backing\nRetain the plastic backing and pouch for storage\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eIngredients\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eMetal, carbon, silicone, hydrogel, and conductive plastic film\u003c\/p\u003e\u003cp\u003eDo not use if you are allergic to any of the materials contained within this product.\nMetal, carbon, silicone, hydrogel, and conductive plastic film \n\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWarnings\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThis device is intended for use by licensed medical professionals, patients, caregivers, or family members assisting with patient care. Users should be capable of comprehending and executing all instructions, warnings, and precautions provided.\u003c\/p\u003e\u003cp\u003eAlthough it is safe for most people, experts recommend that some groups of people avoid TENS treatment unless a doctor advises its use.\n\nThis recommendation applies to the following people:\n\nPregnant women: Pregnant women should avoid using TENS in the abdominal and pelvic regions.\nPeople with epilepsy: Applying electrodes to the head or neck of people with epilepsy may induce seizures.\nPeople with heart problems.\nPeople with a pacemaker or another type of electrical or metal implant.\n\nAvoid placing the pads on bony areas. They work best on muscle or fatty areas. \nClean your skin and let it dry before applying the pads. \nIf you experience redness, itching, or a rash within the first 24 hours, contact your health care provider. \nDon't put the pads on broken or irritated skin.\u003c\/p\u003e\n\u003cdiv\u003e\u003chr\u003e\u003c\/div\u003e\n\u003cp\u003eAlways follow the directions for use. \u003cbr\u003e\u003cbr\u003ePlease refer to any health and product warnings below.\u003c\/p\u003e","brand":"AllCare","offers":[{"title":"Default Title","offer_id":46047823560890,"sku":"8007518","price":163.8,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0756\/8762\/4890\/files\/MP-1-800_8373e18d-ad34-475a-9f75-99cf73037f8c.jpg?v=1782319900","url":"https:\/\/wombatpharmacy.com.au\/products\/allcare-digital-tens-unit-1unit","provider":"Wombat Pharmacy","version":"1.0","type":"link"}